Software optimized for image acquisition and analysis

What’s New

HCImage 4.4.5

Capture

  • Capture Presets– Capture presets can be renamed

Device

  • Thorlabs– DC4100/4104 – 4 channel LED driver

DIA

  • Graphs
    – Added the option to see the “Average of selected all objects”. In the graph legend, average selected objects in a group show as a string of object numbers (e.g., 1-3,15,16,22-25) instead of just selected.
    – Allow user to set the default X-axis range (Field Number or Field Time) when Full or Partial is selected for the display history.
    – Fit will resize the graph to fit the window rather than expand in blocks.
  • Measurement:
    – Added Ratio of Means IM2IM1, Ratio of Means IM4IM3, Mean of Ratio IM2IM1 and Mean of Ratio IM4IM3.
    – Added ratio and image calculation for fluorescence FN. This is the mean gray of the ratio image (Image Field#N / Image Field#1).

Export

  • Expanded Export\Batch Export Options:
    – Export to file type options include: JPEG (.jpg), PNG (.png), and Bitmap (.bmp). Convert to 8-bit required for JPEG and Bitmap images but PNG can be saved as 16-bit.

GUI

  • W-View
    – Set the sub-array of View 2 by dragging ROI
  • High Speed Streaming
    – Improved the Auto Save dialog for DCIMG files.
  • ROI
    – Added “Select All” option (Ctrl+A) and move ROIs with Ctrl+ arrow keys.
    – Expanded cloning capability to create multiple ROIs for well plates.
  • Scalebar Properties
    – Added Best fit button to reset the number of ticks in the Spatial Scalebar.
    – Manually set the Min/Max of the Intensity Scalebar.

Miscellaneous

  • Calibration
    – Added the ability to save the calibration name in Japanese.
  • Copy to Image Document
    – Added the option to split the original image to two separate files.
  • Histogram Display Range
    – Implemented “Display Range” for controlling x-axis of the histogram.
  • Merge
    – Apply LUT to the image and preserve the LUT after merging the images.

HCImage Live 4.4.5

Analysis

  • Measurement
    – Added Ratio of Means IM2IM1, Ratio of Means IM4IM3, Mean of Ratio IM2IM1 and Mean of Ratio IM4IM3.

Capture

  • Capture Presets– Capture presets can be renamed

Export

  • Expanded Export\Batch Export Options:
    – Export to file type options include: JPEG (.jpg), PNG (.png), and Bitmap (.bmp). Convert to 8-bit required for JPEG and Bitmap images but PNG can be saved as 16-bit.

GUI

  • W-View
    – Set the sub-array of View 2 by dragging ROI
  • High Speed Streaming
    – Improved the Auto Save dialog for DCIMG files.
  • ROI
    – Added “Select All” option (Ctrl+A) and move ROIs with Ctrl+ arrow keys.
    – Expanded cloning capability to create multiple ROIs for well plates.
  • Scalebar Properties
    – Added Best fit button to reset the number of ticks in the Spatial Scalebar.
    – Manually set the Min/Max of the Intensity Scalebar.

Miscellaneous

  • Calibration
    – Added the ability to save the calibration name in Japanese.
  • Copy to Image Document
    – Added the option to split the original image to two separate files.
  • Histogram Display Range
    – Implemented “Display Range” for controlling x-axis of the histogram.
  • Merge
    – Apply LUT to the image and preserve the LUT after merging the images.